Home    Products    Specifications    Submittals    Catalog Index    C.A.D.     Test Data     Quotation Request    Contact
 
 
       
   

#358: Drill Bolt™ Brick Veneer Shear Anchoring System

 

Drill Bolts™ are 1/2” thick (12.7mm) in diameter and 6.25" in length. U-Clip is 14 gage. Drill Bolt™ and U-Clip™ are Hotdip Galvanized after fabrication in compliance with ASTM A153 requirement of 1.5 oz/ft2/side (CSA CAN-A370-04 requirement of 460g/m2/side) of zinc coating.

Product Submittal Sheet PDF


PRODUCT FEATURES:

   
 

Expert's Choice for the
Most Innovative Product Award at the 2009 World of Concrete Exhibition!
Complies fully with the Canadian and the US building codes
  • Drill Bolt™ is attached to the stud side; the connecting screws are stressed shear.
  • Load resistance exceeds the requirements of CSA A370 and ACI 530 .
  • The total mechanical free play in the system does not exceed 1.2 mm, as required by CSA A-370.
  • The total sum of displacement under a load of 0.45 KN and mechanical free play in the system does not exceed 2.0 mm, as required by CSA A-370.
  • All parts are hot dip galvanized after fabrication per ASTM A-153, to comply with level 2 corrosion protection requirements as defined in CSA A-370.
 

Rigid insulation integrity remains uninterrupted

  • The Drill Bolt™ creates a very tight penetration without disturbing adjacent sheeting and insulation.
  • U-Clip™ adjusts rotationally from outside to seal the penetration and positively retain the insulation in place.
  • U-Clip™ slot can be installed up or down to allow total vertical adjustment of 2 ¾” (70 mm).
Quick & easy installation
  • The Drill Bolt™ installs with a power drill; the cutting point will penetrate through the sheeting and insulation from inside.
  • The Drill Bolt™ is equipped with a hex head matching the screw hex head so that only one tool is used.
  • The Drill Bolt™ is notched to indicate the depth of insertion required. 
       

Application Profile View

Patent Pending

 
 
     
Triangle Wire Tie
   

#316: Triangle Ties

3/16" dia. (4.76 mm) wire.Closed end is 1" (25.4 mm) wide. Standard Lengths are 3" (76 mm), 4" (102 mm), 5" (127 mm), 7" (178 mm), 9" (229 mm), and 11" (279 mm).

Product Submittal Sheet html
Product Submittal Sheet PDF

Download 2-D Cad File
Download 3-D Cad File

Specification MSWord
Specification PDF

 
   
 
   
Installation
  • Installs from the interior of the building using power drill.
  • Cleanly drills through the sheathing - does not require cutting the sheathing.
  • Notch markings on the bolt designate depth of penetration for various sheathing thickness.
  • Adjustable U-Clip™ seals the hole and allows for vertical adjustment of wire tie.
  • U-Clip™ slot can be installed up or down for a total range of 2-3/4” (69mm) of vertical adjustment
 


1. Use a 5/16” Hex Nut Driver in a power drill


2. From the inside of the building, drill thru the sheathing

3. Stop at the appropriate mark for your sheathing thickness

4. Secure the Drill Bolt to the metal stud with self-drilling/ self-tapping
steel stud screws



5. Drill Bolt on Exterior wall


6. Attach the U-Clip to the Drill Bolt

7. Turn the U-Clip until it is flush with the   insulation


8. Insert wire tie


9. Wire tie placement in brick veneer joint
 
 
Back To Top
 
Home     Products    Specifications    Submittals     CAD Details     Test Data     PDF Files
Catalog Index  
   M.S.D.S.     Credit App.     Links     Trades Shows     Quotation Request     Contact     History